On Wed, Nov 16, 10:04, Tommi Virtanen wrote: > On Wed, Nov 16, 2011 at 01:56, Andre Noll <maan@xxxxxxxxxxxxxxx> wrote: > >> 2) I wouldn't expect your OSDs to have become so unbalanced that one > >> of them hits 95% full when the cluster's only at 84% capacity. > > > > This seems to be due to the fact that roughly the same amount of data > > was written to each file system despite of the different file system > > sizes. Hence only 60% disk space is used on the two 800G file systems. > > That would be it. You probably want to set the weights of your OSDs > according to their storage capacity, otherwise the smaller ones will > get filled first. > > http://ceph.newdream.net/wiki/Monitor_commands#reweight I was under the impression that equal weights on all osds means to fill up all file systems by the same percentage, i.e. that file system sizes are already taken care of. But apparently this is not the case. So one has to set the weights manually according to the available disk space. Thanks for enlightening me. Andre -- The only person who always got his work done by Friday was Robinson Crusoe