2009/3/13 Ross Walker <rswwalker@xxxxxxxxx>: > With open-iscsi you will need to use multiple iSCSI sessions over > different subnets and dm-multipath. Configure 2 portal addresses one > in each subnet. If Equalogics sets the SCSI Ids correctly then dm- > multipath will match them up. Set a round-robin policy on the paths > and test/tune accordingly (path delays, # blocks per path, etc). I have tried using separate subnets on the different interfaces on the Equallogic box and host - but the client host would still only find the volume once. I've now heard back from Dell - and it appears it can't be done with the software initiator on CentOS4/RHEL4 - but should work with CentOS5 Thanks James _______________________________________________ CentOS mailing list CentOS@xxxxxxxxxx http://lists.centos.org/mailman/listinfo/centos