Re: C5 64-bit and software RAID 6?

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]



Scott R. Ehrlich wrote:
I have a Dell PowerEdge 2950 with 6 SAS disks and a PERC 5/i controller what won't do RAID 6. I plan to have 2 drives as RAID 1 for the OS, and the remaining 4 as RAID 6. Granted the PERC can do RAID 1, I'm tempted to do everything via software RAID. Thus, if anything goes wrong with the controller, I just need to obtain a new SAS controller and I'm back up.

4 disks in RAID 6? Isn't this a bit overkill? You would use half
the space for RAID checksums.

If it were me, I would:

Partition all drives identically with a 200M partition 1
and the rest as partition 2

Use sda1 and sdb1 in RAID 1 as /boot
Use sd[cdef]1 as swap in RAID 5
Use sd[abcdef]2 as / in RAID 5

You could use RAID 6 for /, but then you're not 100%
safe if you loose disks 1 and 2 simultaneously.

Mogens

--
Mogens Kjaer, Carlsberg A/S, Computer Department
Gamle Carlsberg Vej 10, DK-2500 Valby, Denmark
Phone: +45 33 27 53 25, Fax: +45 33 27 47 08
Email: mk@xxxxxx Homepage: http://www.crc.dk