I updated my backup server to CentOS 6.6 this morning. As usual, I
unmounted the current (nightly) tape from the changer before the
reboot. Now Bacula complains it cannot access the changer:
3301 Issuing autochanger "loaded? drive 0" command.
3991 Bad autochanger "loaded? drive 0" command: ERR=Child exited with code 1.
Results=cannot open SCSI device '/dev/changer' - Permission denied
SELinux is denying source context bacula_t from accessing target
context tape_device_t. I took a look at the various SELinux boolean
values but see none that applies.
Has anyone else observed this symptom since upgrading?
Is there a fix other than building a local policy by going through the
"ausearch | audit2allow" iteration(s)?
--
Paul Heinlein
heinlein@xxxxxxxxxx
45°38' N, 122°6' W
_______________________________________________
CentOS mailing list
CentOS@xxxxxxxxxx
http://lists.centos.org/mailman/listinfo/centos