On 12/22/11 3:28 PM, Joseph L. Casale wrote: >> i'm configuring a storage server with CentOS 6.2, it uses a LSI MegaRAID >> >SAS controller, I'm using LSI's megacli to configure the storage... >> >Any ideas on how to get drive failure notifications out of this >> >system? I'm configuring hot spares but I'd still like some sort of >> >notification when a drive has failed so the spare can be replaced. > I've tried countless times to get the LSI snmp agent designed just for this > to work in CentOS 5 and 6, no luck. > > Resorted to a pathetic snmp extend that runs megacli, sigh... I just installed the Linux MSM package from LSI... I had to add these packages to a minimal 6.2 install for what its worth... * yum install libstdc++.i686 compat-libstdc++-33.i686 libX11 libX11.i686 libXi libXi.i686 libXtst libXtst.i686 xauth net-snmp net-snmp-utils csh The X stuff was required by the GUI manager, I suspect if you did a agent-only install, that wouldn't be needed. I'm a total novice when it comes to snmp. but i'm reading some howto's and stumbling around. -- john r pierce N 37, W 122 santa cruz ca mid-left coast _______________________________________________ CentOS mailing list CentOS@xxxxxxxxxx http://lists.centos.org/mailman/listinfo/centos