we have several R900 servers with PERC 6/E card in it. Recently it we getting some message on /var/log/message say change to "write back" and change back to "write through". We figure out it is PERC 6/E card battery weak. My questions are: 1. some battery only use one year (some even shorter) and already this problem. 2. How come PERC 5/E does not have this issue? 3. where is DISK array information store for PERC 6/E? I did NOT see NVRAM on PERC 6/E card. 4. when replace PERC 6/E card and power on server sometime it will ask you "import configuration" ans some time it won't. Why? 5. When replace PERC 6/E card and power on. Server ask "import configuration" should I answer "yes"? 6. where can I find documentation which mention "import configuration"? Thanks. _______________________________________________ CentOS mailing list CentOS@xxxxxxxxxx http://lists.centos.org/mailman/listinfo/centos