On 12/27/10 9:09 PM, robert mena wrote: > Regular realtek fast ethernet. IMNSHO, realtek are pretty close to junk grade NICs. they have far too many variations with far too many weird bugs when used for any more than single user desktop kind of systems. > Each one connected to a broadband modem (1 Mbps each) so I do not > think this should be a bus saturation. what speed is the local link to the modem? even if your internet connection is 1Mbps, if your ethernet is running at 100baseT, that can be 10MB/sec bursts, and a few of those could potentially cause bus contention issues how fast is the LAN? since the errors were on eth3 and eth4, I'm wondering what eth0, eth1, and eth2 are doing traffic wise. > I do not think this is a thermal problem due to the lack of messages > (I got this problem in the past with a different machine and I got > those overheating message - with the throttle but I'll investigate > further. > I wouldn't rely on that assumption. Thermal monitoring might not be configured correctly for this board, etc etc. _______________________________________________ CentOS mailing list CentOS@xxxxxxxxxx http://lists.centos.org/mailman/listinfo/centos