[PATCH bpf-next] selftests/bpf: Fix bpf_nf failure upon test rerun

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Alexei reported:

  After fast forwarding bpf-next today bpf_nf test started to fail when
  run twice:

  $ ./test_progs -t bpf_nf
  #17      bpf_nf:OK
  Summary: 1/10 PASSED, 0 SKIPPED, 0 FAILED

  $ ./test_progs -t bpf_nf
  All error logs:
  test_bpf_nf_ct:PASS:test_bpf_nf__open_and_load 0 nsec
  test_bpf_nf_ct:PASS:iptables-legacy -t raw -A PREROUTING -j CONNMARK
  --set-mark 42/0 0 nsec
  (network_helpers.c:102: errno: Address already in use) Failed to bind socket
  test_bpf_nf_ct:FAIL:start_server unexpected start_server: actual -1 < expected 0
  #17/1    bpf_nf/xdp-ct:FAIL
  test_bpf_nf_ct:PASS:test_bpf_nf__open_and_load 0 nsec
  test_bpf_nf_ct:PASS:iptables-legacy -t raw -A PREROUTING -j CONNMARK
  --set-mark 42/0 0 nsec
  (network_helpers.c:102: errno: Address already in use) Failed to bind socket
  test_bpf_nf_ct:FAIL:start_server unexpected start_server: actual -1 < expected 0
  #17/2    bpf_nf/tc-bpf-ct:FAIL
  #17      bpf_nf:FAIL
  Summary: 0/8 PASSED, 0 SKIPPED, 1 FAILED

I was able to locally reproduce as well. Rearrange the connection teardown
so that the client closes its connection first so that we don't need to
linger in TCP time-wait.

Fixes: e81fbd4c1ba7 ("selftests/bpf: Add existing connection bpf_*_ct_lookup() test")
Reported-by: Alexei Starovoitov <ast@xxxxxxxxxx>
Signed-off-by: Daniel Borkmann <daniel@xxxxxxxxxxxxx>
Link: https://lore.kernel.org/bpf/CAADnVQ+0dnDq_v_vH1EfkacbfGnHANaon7zsw10pMb-D9FS0Pw@xxxxxxxxxxxxxx
---
 tools/testing/selftests/bpf/prog_tests/bpf_nf.c | 5 +++--
 1 file changed, 3 insertions(+), 2 deletions(-)

diff --git a/tools/testing/selftests/bpf/prog_tests/bpf_nf.c b/tools/testing/selftests/bpf/prog_tests/bpf_nf.c
index c8ba4009e4ab..b30ff6b3b81a 100644
--- a/tools/testing/selftests/bpf/prog_tests/bpf_nf.c
+++ b/tools/testing/selftests/bpf/prog_tests/bpf_nf.c
@@ -123,12 +123,13 @@ static void test_bpf_nf_ct(int mode)
 	ASSERT_EQ(skel->data->test_snat_addr, 0, "Test for source natting");
 	ASSERT_EQ(skel->data->test_dnat_addr, 0, "Test for destination natting");
 end:
-	if (srv_client_fd != -1)
-		close(srv_client_fd);
 	if (client_fd != -1)
 		close(client_fd);
+	if (srv_client_fd != -1)
+		close(srv_client_fd);
 	if (srv_fd != -1)
 		close(srv_fd);
+
 	snprintf(cmd, sizeof(cmd), iptables, "-D");
 	system(cmd);
 	test_bpf_nf__destroy(skel);
-- 
2.34.1