On Wed, 17 Jun 2020 at 07:49, John Fastabend <john.fastabend@xxxxxxxxx> wrote: > > Alexei Starovoitov wrote: > > On Tue, Jun 16, 2020 at 1:30 AM Lorenz Bauer <lmb@xxxxxxxxxxxxxx> wrote: > > > > > > On Tue, 16 Jun 2020 at 04:55, Alexei Starovoitov > > > <alexei.starovoitov@xxxxxxxxx> wrote: > > > > > > > > On Mon, Jun 15, 2020 at 7:43 AM Lorenz Bauer <lmb@xxxxxxxxxxxxxx> wrote: > > > > > > > > > > On Fri, 12 Jun 2020 at 23:36, Alexei Starovoitov > > > > > <alexei.starovoitov@xxxxxxxxx> wrote: > > > > > > > > > > > > On Fri, Jun 12, 2020 at 9:02 AM Lorenz Bauer <lmb@xxxxxxxxxxxxxx> wrote: > > > > > > > > > > > > > > Using BPF_PROG_ATTACH on a flow dissector program supports neither flags > > > > > > > nor target_fd but accepts any value. Return EINVAL if either are non-zero. > > > > > > > > > > > > > > Signed-off-by: Lorenz Bauer <lmb@xxxxxxxxxxxxxx> > > > > > > > Fixes: b27f7bb590ba ("flow_dissector: Move out netns_bpf prog callbacks") > > > > > > > --- > > > > > > > kernel/bpf/net_namespace.c | 3 +++ > > > > > > > 1 file changed, 3 insertions(+) > > > > > > > > > > > > > > diff --git a/kernel/bpf/net_namespace.c b/kernel/bpf/net_namespace.c > > > > > > > index 78cf061f8179..56133e78ae4f 100644 > > > > > > > --- a/kernel/bpf/net_namespace.c > > > > > > > +++ b/kernel/bpf/net_namespace.c > > > > > > > @@ -192,6 +192,9 @@ int netns_bpf_prog_attach(const union bpf_attr *attr, struct bpf_prog *prog) > > > > > > > struct net *net; > > > > > > > int ret; > > > > > > > > > > > > > > + if (attr->attach_flags || attr->target_fd) > > > > > > > + return -EINVAL; > > > > > > > + > > > > > > > > > > > > In theory it makes sense, but how did you test it? > > > > > > > > > > Not properly it seems, sorry! > > > > > > > > > > > test_progs -t flow > > > > > > fails 5 tests. > > > > > > > > > > I spent today digging through this, and the issue is actually more annoying than > > > > > I thought. BPF_PROG_DETACH for sockmap and flow_dissector ignores > > > > > attach_bpf_fd. The cgroup and lirc2 attach point use this to make sure that the > > > > > program being detached is actually what user space expects. We actually have > > > > > tests that set attach_bpf_fd for these to attach points, which tells > > > > > me that this is > > > > > an easy mistake to make. > > In sockmap case I didn't manage to think what multiple programs of the same type > on the same map would look like so we can just remove whatever program is there. > Is there a problem with this or is it that we just want the sanity check. > > > > > > > > > > > Unfortunately I can't come up with a good fix that seems backportable: > > > > > - Making sockmap and flow_dissector have the same semantics as cgroup > > > > > and lirc2 requires a bunch of changes (probably a new function for sockmap) > > > > > > > > making flow dissector pass prog_fd as cg and lirc is certainly my preference. > > > > Especially since tests are passing fd user code is likely doing the same, > > > > so breakage is unlikely. Also it wasn't done that long ago, so > > > > we can backport far enough. > > > > It will remove cap_net_admin ugly check in bpf_prog_detach() > > > > which is the only exception now in cap model. > > > > > > SGTM. What about sockmap though? The code for that has been around for ages. > > > > you mean the second patch that enforces sock_map_get_from_fd doesn't > > use attach_flags? > > I think it didn't break anything, so enforcing is fine. > > I'm ok with enforcing it. > > > > > or the detach part that doesn't use prog_fd ? > > I'm not sure what's the best here. > > At least from cap perspective it's fine because map_fd is there. > > > > John, wdyt? > > I think we can keep the current detach without the prog_fd as-is. And > then add logic so that if the prog_fd is included we check it? Do you know of users that rely on this? FWIW all of the selftests actually pass attach_bpf_fd when detaching from sockmap (on a recent bpf-next at least). It'd be nice if I could make sockmap require this to be present, just so that it's consistent with flow_dissector and other BPF_PROG_DETACH users. OTOH I'm not sure if this is backport material after all. Lorenz -- Lorenz Bauer | Systems Engineer 6th Floor, County Hall/The Riverside Building, SE1 7PB, UK www.cloudflare.com