Info request on Raid 1 on RH 7.2 and promise Raid controller

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



 
I tried to install Linux RedHat 7.2 on a Asus A7V266-E Motherboard equipped
with Promise PDC20265R Raid controller in raid 1.
 
What is the way to understand if the raid 1 is running ok !
I done:
1) I have two equal 58 GB HD connected on ide2 and ide3. I enabled raid 1 at bios level by Fast Build Utility.
2) At boot time linux see the two HD ide2 --> /dev/hde and ide3 --> /dev/hdg. I loaded RH 7.2 linux on the first HD /dev/hde.
3)I rebuild the same kernel  (2.4.7 - 10) including some drives :
     CONFIG_BLK_DEV_PDC202XX (promise support)
     CONFIG_PDC202XX_FORCE
     support for IDE Raid controller
     support promise software RAID (Fasttrack(tm))
4) The system do not from hd. It boot only from floppy (with new kernel image. I installed the new kernel in to /boot partition.
5) I duplicated the first HD in to second HD  at bios level by Fast Build Utility.
6) Now the system boot ok from HD. The file messages tell :
 
        ........ : PDC20265: IDE controller on PCI bus 00 dev 30
        ........
             ........
        ........ ide: Found promise 20256 in Raid mode.
             ........
             ........ : Promise Fasttrack(tm) Softwareraid driver for linux version 0.02
            
        ........ : No rain arry found
        ..... md : raid1 personality registered as nr 3
        .........
 
        ......... 
 
        ..... md : Autodetecting RAID arrays.
        ..... md : autorun ...
        ..... md : ... autorun DONE.
        ........
        ........
 
 
 