Sriram, Ask the Telco if they can support 2 independant nodes with the same Point Code. Use F-links and guarantee that CIC's used are on the same 8-E1 bundle as the SS7 call etc. Not sure, but it might work. Jan From: d_r_sriram@xxxxxxxxxxx To: asterisk-ss7 at lists.digium.com Date: Wed, 26 Jan 2011 23:10:07 +0530 Subject: 16 E1s LibSS7 Hi List I am using Libss7 with asterisk 1.6.0 and TE420P and its working quite well handling around 50K calls per day on a single box for past 1 year. I?ve an additional requirement now from the telco. They want me to expand the box to 16E1s but are giving only 1 Point code. My question is : Is it suicidal to run 16 E1s on single box on LibSS7. there will be no transcoding as all calls would be on E1s [both inbound and outbound] but MySQL is used in backed? I am planning to plug 2 Sangoma 8 E1 cards and use LibSS7 will it have any performance issues ? If the above setup is not recommended ? is it possible to use 2 boxes with 8 e1s each with 1 single point code ? I heard somewhere that Libss7 currently allows only 1 point code per server . Thanks Sriram -- _____________________________________________________________________ -- Bandwidth and Colocation Provided by http://www.api-digital.com -- asterisk-ss7 mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-ss7 -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.digium.com/pipermail/asterisk-ss7/attachments/20110127/13bd3f05/attachment.htm>