Hi,

I've got a server with two quad port Digium cards in.  I have 
successfully configured a single port to connect via SS7 to an Alcatel 
IN switch.  However, I also have a Huawei switch that I need to connect 
to.  The plan is to connect 4 ports to the Alcatel and 4 ports to the 
Huawei.

Is the linkset=X setting comparable to the group=X setting using for PRI 
configuration? 
Will any settings between linkset lines apply to that particular linkset?

My configuration is currently as follows-

[channels]
context=from-ss7
signalling = ss7
ss7type = itu
linkset = 1
pointcode = 760
adjpointcode = 900
defaultdpc = 900
ss7_called_nai=dynamic
ss7_calling_nai=dynamic
networkindicator=national
cicbeginswith = 1
channel = 1-15
cicbeginswith = 17
channel = 17-31
sigchan = 16


Regards,
Ian






[Index of Archives]     [Asterisk App Development]     [PJ SIP]     [Gnu Gatekeeper]     [IETF Sipping]     [Info Cyrus]     [ALSA User]     [Fedora Linux Users]     [Linux SCTP]     [DCCP]     [Gimp]     [Yosemite Backpacking]     [Deep Creek Hot Springs]     [Yosemite Campsites]     [ISDN Cause Codes]     [Asterisk Books]