Single Point Code across Multiple * Boxes.

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,
>> Hi Matthew,
>>
>> In this case, if the point code is distributed across more than one box, 
>> how do you manage SS7 link (and linkset) failures, where the messages 
>> need to be re-routed via another link (or linkset) during failure scenarios?
>
> Well, to have a fully redundant setup, you would have separate boxes 
> terminating each signaling link.  These routing machines can masquerade 
> ISUP traffic over to other machines via IP protocol based links.  Each 
> of these IP connected boxes has an IP link to each box with a physical 
> signaling link.  If a machine with a physical link goes down, it reports 
> it to the IP links that are hooked up to it and the machines using those 
> IP links use their alternate IP links instead of that link, providing 
> for redundancy in times of link failure.
Have you looked at the RSerPool 
(http://www.ietf.org/html.charters/rserpool-charter.html). It may be one 
method of addressing these requirements.

> There are going to be other problems to think about as well, but I think 
> that the basic logic is sound and will work.
>
> I actually just got masqueraded ISUP messages passing correctly back and 
> forth over IP, but I still have some technical hurdles as far as what to 
> do as IP links go in and out of service.  This list will definitely know 
> what I have something I'm interested in testing :-)
What about using M3UA to address the requirement of having one point 
code across more than one box? The Routing Key registration method 
provided for in M3UA will allow each box to register the CIC values for 
which they want to receive ISUP messages. See the example architecture 
with M3U1 below. Box1 (ASP1) would register a routing key for CIC 1..93, 
Box2 (ASP2) would register a routing key for CIC 94..186, and Box3 
(ASP3) would register a routing key for CIC 187..279. The E1s/T1s from 
each SEP to each Box/ASP would still exist, however we would terminate 
the SS7 on a Signalling Gateway and route M3UA between the SG and each 
ASP. (The example below shows one SG but at least 2 will be necessary).

                                                              ----
                                                            /      \
                                                       /---+  ASP1  |
                                                      /     \      /
                                SG                   /        ----
                               +---------------+    /
                               |          |    |---/          ----
        +-------+   SS7 links  |          |    |            /      \
        |  SEP  +--------------| SS7 Ntwk.|M3UA+-----------+  ASP2  |
        +-------+              |          |    |            \      /
                               |          |    |              ----
                               |          |    |---\
                               +---------------+    \         ----
                                                     \      /      \
                                                      \----+  ASP3  |
                                                            \      /
                                                              ----


Best Regards,
Amish Chana





[Index of Archives]     [Asterisk App Development]     [PJ SIP]     [Gnu Gatekeeper]     [IETF Sipping]     [Info Cyrus]     [ALSA User]     [Fedora Linux Users]     [Linux SCTP]     [DCCP]     [Gimp]     [Yosemite Backpacking]     [Deep Creek Hot Springs]     [Yosemite Campsites]     [ISDN Cause Codes]     [Asterisk Books]