Kristian Nielsen wrote: > Robert Verspuy <robert at exa-omicron.nl> writes: > > >> [Sep 29 11:24:21] WARNING[2330]: mtp.c:940 timeout_sltm_t1: No SLTA >> received within Q.707 timer T1, trying again on link 'a'. >> > > This has been covered in several threads in the past, you might want to check > the archives. > > In short, the other end is not properly doing the SLTR/SLTA part of > SS7. Either disable slta checking on your end, or get the other end to enable > it. > > After some searching I found the "sltm => no" config parameter, just like Grant mailed. With this option, I do see some more traffic. But I receive "circuit group reset"'s coming from a different pointcode then the signalling point code. chan_ss7 does not act on these resets, because it's probably not the source pointcode. ?? In the mean time, I got some more information. It seems, that I have to setup the signalling to pointcode x, and the voice channels to pointcode y. But how do I set that up? I would think to create 2 links. One for signalling, and one for the voice channels. And combine them into one linkset, But I can only configure one pointcode per linkset, right? Thnx in advance, Robert -- *Exa-Omicron* Patroonsweg 10 3892 DB Zeewolde Tel.: 088-OMICRON (66 427 66) http://www.exa-omicron.nl
![]() |