The telecom at the moment will not allow us to put traffic on the link until the problem has been rectified . This is part of what they sent me: FRAME STATUS: 'some frames have been lost' | |MTP Level 2 (MTP-L2) FISU (= Fill In Signal Unit) On Sep 23, 2008, at 9:38 PM, Matthew Fredrickson wrote: > Markus A. Wipfler wrote: >> Hi all, >> >> I am getting below error when running ss7linktest : >> >> Unable to process message destined for userpart 3; dropping message >> >> My first assumption was that it is a link error, but when I check for >> line/bit errors everything seems fine. > > No, this is not a link error, this is an SCCP user part message that > we > were sent from the other end. We don't have an SCCP stack right now, > which is why we print a message and drop it. Am thinking of asking the telecom to suppress those messages, because we are only going to do a basic interconnect. > >> Also, telecom at there end see dropped packets, but don't go into any >> details. > > Can you describe the problem (more exactly) that you are having > better? > (other than the SCCP part) At the moment I cannot give any more details coz we cannot even make a test call until this is sorted. Will keep you posted. > > > Thanks, > Matthew Fredrickson > Digium, Inc. > > > > > _______________________________________________ > --Bandwidth and Colocation Provided by http://www.api-digital.com-- > > asterisk-ss7 mailing list > To UNSUBSCRIBE or update options visit: > http://lists.digium.com/mailman/listinfo/asterisk-ss7