Daniel Bichara wrote: > Dear Matthew, > > We detected 2 problems we tried to work around: > > 1) We were getting echo on SS7 calls (no matter the echo-canceler we > configured). I detected echo canceler was not activated during call setup. > > 2) Connecting same linkset to more than one DPC (different E1s), when > replying SS7 messages addressed to a CIC associated to one DPC, the > answer message included wrong PC address. > > Attached my libss7 patches and chan_zap. These patches are running last > 3 weeks with no problem. > > Please validate them. First of all, thanks for your hard work in not only finding those issues but also finding a fix for them. Secondly, as Kevin mentioned in another message, please post your patch to the bugs.digium.com bug tracker so that it can be evaluated and committed. I can't really use your patch unless it has properly gone through that submission process. -- Matthew Fredrickson Software/Firmware Engineer Digium, Inc.