Hello Mitul, On 16.01.2007 22:15, Mitul Limbani wrote: [...] > after which i thought to degrade to chan_ss7-0.8.4.tar.gz, and voila, my > calls started maturing, but still, I keep on seeing the following on CLI > ALL the while > > ------------------------------------------------------------------- > Jan 16 21:33:51 NOTICE[9731]: mtp.c:1227 mtp2_read_su: MTP2 CRC error > (CRC=0x74b0 != 0xf0b8) on link 'g1'. [...] > I would like to know if any one faced this, i also surfed through > archives, but that issue was pertaining to some IRQ issues but my > machine has seperate IRQ for my TE110P card. I had a very similar problem with a system with a TE210P and was struggling quite some time to get behind it. It finally turned out that my card was broken. I changed the card and the CRC-Problems were gone. (See my mail from 07/07/06 with the subject "[asterisk-ss7] Strange interrupt issue with zaptel and chan_ss7" and following mails) I think (if I am wrong please correct me) the reason that this happens quite often with chan_ss7 is, that in SS7 one channel (time slot) is used with its complete bandwidth of 64k all the time to do the signaling. IIRC that is not the case in PRIs, so it is possible that more cards are broken, but the problem simply does not show because of less used bandwidth. Just my .02$ Regards Kai -- Kai Militzer WESTEND GmbH | Internet-Business-Provider Technik CISCO Systems Partner - Authorized Reseller L?tticher Stra?e 10 Tel 0241/701333-14 km@xxxxxxxxxxx D-52064 Aachen Fax 0241/911879