On Sun, Oct 20, 2019 at 1:38 PM Cezary Rojewski <cezary.rojewski@xxxxxxxxx> wrote: > > On 2019-10-18 22:04, Curtis Malainey wrote: > > Use the PLL to kept the correct 24M clock rate so frequency shift does > > not occur when using the DSP VAD. > > > > > +static int bdw_rt5677_dsp_hw_params(struct snd_pcm_substream *substream, > > + struct snd_pcm_hw_params *params) > > +{ > > + struct snd_soc_pcm_runtime *rtd = substream->private_data; > > + struct snd_soc_dai *codec_dai = rtd->codec_dai; > > + int ret; > > + > > + ret = snd_soc_dai_set_sysclk(codec_dai, RT5677_SCLK_S_PLL1, 24576000, > > + SND_SOC_CLOCK_IN); > > + if (ret < 0) { > > + dev_err(rtd->dev, "can't set codec sysclk configuration\n"); > > + return ret; > > + } > > + ret = snd_soc_dai_set_pll(codec_dai, 0, RT5677_PLL1_S_MCLK, > > + 24000000, 24576000); > > + if (ret < 0) { > > + dev_err(rtd->dev, "can't set codec pll configuration\n"); > > + return ret; > > nitpick: you may skip "return ret" here and drop parenthesis as > function's final line does the job. > > > + } > > + > > + return ret; > > If you decide to stick with leaving above as is, explicitly returning 0 > would be preferred. > fair enough, if there are no issues with the patch series I can follow it up with a quick change to return 0. > > > +} _______________________________________________ Alsa-devel mailing list Alsa-devel@xxxxxxxxxxxxxxxx https://mailman.alsa-project.org/mailman/listinfo/alsa-devel