On Fri, Jul 26, 2019 at 01:08:57PM -0500, Pierre-Louis Bossart wrote: > This thread became unreadable with interleaved top-posting, allow me restate > the options and ask PM folks what they think > > On 7/25/19 6:40 PM, Pierre-Louis Bossart wrote: > > Not all platforms support runtime_pm for now, let's use runtime_pm > > only when enabled. Just a side note below... > > - ret = pm_runtime_get_sync(slave->bus->dev); > > - if (ret < 0) Here... > > - return ret; > > + if (pm_runtime_enabled(slave->bus->dev)) { > > + ret = pm_runtime_get_sync(slave->bus->dev); > > + if (ret < 0) ...and thus here... > > + return ret; > > + } > > ret = sdw_transfer(slave->bus, &msg); > > - pm_runtime_put(slave->bus->dev); > > + > > + if (pm_runtime_enabled(slave->bus->dev)) > > + pm_runtime_put(slave->bus->dev); > > This is option1: we explicitly test if pm_runtime is enabled before calling > _get_sync() and _put() > > option2 (suggested by Jan Kotas): catch the -EACCESS error code > > ret = pm_runtime_get_sync(slave->bus->dev); > - if (ret < 0) > + if (ret < 0 && ret != -EACCES) ...and here, the pm_runtime_put_noidle() call is missed. > return ret; > > option3: ignore the return value as done in quite a few drivers > > Are there any other options? I am personally surprised this is not handled > in the pm_runtime core, not sure why users need to test for this? -- With Best Regards, Andy Shevchenko _______________________________________________ Alsa-devel mailing list Alsa-devel@xxxxxxxxxxxxxxxx https://mailman.alsa-project.org/mailman/listinfo/alsa-devel