On 09/03/2018 06:30 AM, Mark Brown wrote:
> On Fri, Aug 31, 2018 at 01:17:37PM -0500, Andrew F. Davis wrote:
>> The notification handler sets the reset line but never re-enables it
>> as no one is listening for an enable event, this is certainly broken
>> and was most likely just copied from other CODECs, remove this code.
> 
> Why not fix it?  The usual pattern would be to take the CODEC out of
> reset when bringing the bias back to standby.
> 

The only time this code gets called outside of the normal power on/off
path is regulator_force_disable(). And the enable event is only called
inside regulator_enable() which would already be part of the normal
power up path.

I still don't see the need for this code at all, I do not want to fix
unused broken code, and if no one else will fix it, the code should be
dropped.