On Wed, Feb 21, 2018 at 09:11:34PM +0100, Hans de Goede wrote: > On 21-02-18 12:43, Mark Brown wrote: > > On Tue, Feb 20, 2018 at 11:15:04PM +0100, Hans de Goede wrote: > > > There is no need to set the LDO voltage to 1.2 volt each time we enter > > > standby, instead always leave it 1.2 volt on BIAS_OFF. Note we do a > > > snd_soc_codec_force_bias_level(BIAS_OFF) on probe, so this will configure > > > it correctly right from the start. > > That force on probe sounds like a problem... if this is being done once > > at startup it should be done in the probe function, not in the bias > > level configuration. > This is more like "we do a snd_soc_codec_force_bias_level(BIAS_OFF) > on probe anyways and that already sets the level to 1.2 volt, so > we don't need to do this explicitly at probe time". What I'm saying is that if the code is written such that you need to do that _force_bias_level() then it's not very idiomatic which is a bit worrying - it might be safer to reorganize the code so that this isn't required any more. > > Also, are you sure this is a good fix? If the bias voltage is being > > configured all the time does that perhaps indicate that for better > > performance or something it should have been being set to some other > > voltage when the device is in standby? > We switch the LDO off when in the bias level is BIAS_OFF and on > at 1.2 volt when in standby or higher. Before this commit we would OK.
Attachment:
signature.asc
Description: PGP signature
_______________________________________________ Alsa-devel mailing list Alsa-devel@xxxxxxxxxxxxxxxx http://mailman.alsa-project.org/mailman/listinfo/alsa-devel