Hi Nicolin,
On Wed, Sep 06, 2017 at 11:22:48AM +0200, Łukasz Majewski wrote:
Here is the routine that I understood from the code:
1) asoc_simple_card_parse_clk_cpu(dev, cpu, dai_link, cpu_dai);
=> asoc_simple_card_parse_clk(dev, cpu, // cpu node in sound{} [1]
dai_link->cpu_of_node, // node ssi2 [2]
cpu_dai, dai_link->cpu_dai_name);
==> 1.1) devm_get_clk_from_child(dev, node, NULL); // [1]
==> 1.2) of_property_read_u32(node, "system-clock-frequency", &val)// [1]
==> 1.3) devm_get_clk_from_child(dev, dai_of_node, NULL); // [2]
For the cpu routine, it first checks for clock property under cpu
node of simple-card, then for "system-clock-frequency" in the cpu
node of simple-card, and finally looks for clock property in ssi2
node.
-----> dev: sound
-----> clk node: /soc/aips-bus@02000000/spba-bus@02000000/ssi@0202c000
-----> Clk asignment
And this clock is taken from this node. It looks like ipg clock for ssi...
This makes sense now. The devm_get_clk_from_child() in 1.3) fetched
the first clock of ssi2 -- ipg clock.
Yes, exactly (for SSI2) [1]:
clocks = <&clks IMX6QDL_CLK_SSI2_IPG>,
<&clks IMX6QDL_CLK_SSI2>;
clock-names = "ipg", "baud";
The problem is with the "lack" of clock nodes/properties at
dailink_master: cpu {
sound-dai = <&ssi2>;
clock = <&SSSS>;
If possible I do prefer a solution, which uses only DTS.
Side question - how to refer to baud clock from [1]?
system-clock-frequency = <XXXX>;
};
This is the right solution based on current simple-card driver. For
SSI (having two clocks), you have to specify the baud clock in the
cpu node like that. I believe this is what the simple-card designer
expected users to do since the cpu node is the first place that the
driver tries to look at.
I will give a shoot the option with adding the ipg clock.
I think that the proper solution would be to add check for:
freq < sysclk/5 in fsl_ssi_set_dai_sysclk() and return -ENOTSUPP to
make the simple-audo-card driver happy (and not introducing
regressions).
As I said in the first place, adding another check in set_sysclk()
is not that essential but seems to be plausible to me. So I am okay
if you really want to have that.
Thanks for help.
--
Best regards,
Lukasz Majewski
--
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd@xxxxxxx
_______________________________________________
Alsa-devel mailing list
Alsa-devel@xxxxxxxxxxxxxxxx
http://mailman.alsa-project.org/mailman/listinfo/alsa-devel