On Tue, Apr 19, 2016 at 2:46 AM, Mark Brown <broonie@xxxxxxxxxx> wrote: > On Mon, Apr 18, 2016 at 01:20:35PM -0700, anish kumar wrote: >> On Mon, Apr 18, 2016 at 9:47 AM, Mark Brown <broonie@xxxxxxxxxx> wrote: > >> > As I said last time I would expect this to be a TLV control. As far as >> > I can tell this is basically functioning as a maximum volume. Otherwise >> > this looks good. > >> I responded to your comment earlier but there was no reply so I thought >> it is accepted this way. Excuse my understanding. It is not actually a volume >> but described as such. > > If it's measured in dB I'd still expect a TLV control. > >> It is "Speaker No-Load Output Voltage Maximum". It is >> described here on page 50. >> https://datasheets.maximintegrated.com/en/ds/MAX98371.pdf > > Hrm, that looks like the driver may be able to set it automatically > using the regulator API and just have a switch for the guaranteed. Should i pass it via device tree then? I didn't get your statement about "switch". _______________________________________________ Alsa-devel mailing list Alsa-devel@xxxxxxxxxxxxxxxx http://mailman.alsa-project.org/mailman/listinfo/alsa-devel