Hi, On Nov 02 2015 15:55, Julia Lawall wrote:
Move constant to the right of binary operators. Generated by: scripts/coccinelle/misc/compare_const_fl.cocci CC: Takashi Sakamoto <o-takashi@xxxxxxxxxxxxx> Signed-off-by: Fengguang Wu <fengguang.wu@xxxxxxxxx> Signed-off-by: Julia Lawall <julia.lawall@xxxxxxx> --- Depends on personal taste, but the modified version does look a little nicer to me, since one can better see the relationship between the fdf and sfc fields. amdtp-am824.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) --- a/sound/firewire/amdtp-am824.c +++ b/sound/firewire/amdtp-am824.c @@ -36,7 +36,7 @@ int amdtp_am824_set_parameters(struct am if (err < 0) return err; - s->fdf = AMDTP_FDF_AM824 | s->sfc; + s->fdf = s->sfc | AMDTP_FDF_AM824; /* * In IEC 61883-6, one data block represents one event. In ALSA, one
Could I request explainations about the advantage of this modification? I cannot imagine good reasons for this subtle changes...
Regards Takashi Sakamoto _______________________________________________ Alsa-devel mailing list Alsa-devel@xxxxxxxxxxxxxxxx http://mailman.alsa-project.org/mailman/listinfo/alsa-devel