On Mon, 29 Jan 2024 13:12:54 +0100, Alexander Tsoy wrote: > > Many devices with a single alternate setting do not have a Valid > Alternate Setting Control and validation performed by > validate_sample_rate_table_v2v3() doesn't work on them and is not > really needed. So check the presense of control before sending > altsetting validation requests. > > MOTU Microbook IIc is suffering the most without this check. It > takes up to 40 seconds to bootup due to how slow it switches > sampling rates: > > [ 2659.164824] usb 3-2: New USB device found, idVendor=07fd, idProduct=0004, bcdDevice= 0.60 > [ 2659.164827] usb 3-2: New USB device strings: Mfr=1, Product=2, SerialNumber=0 > [ 2659.164829] usb 3-2: Product: MicroBook IIc > [ 2659.164830] usb 3-2: Manufacturer: MOTU > [ 2659.166204] usb 3-2: Found last interface = 3 > [ 2679.322298] usb 3-2: No valid sample rate available for 1:1, assuming a firmware bug > [ 2679.322306] usb 3-2: 1:1: add audio endpoint 0x3 > [ 2679.322321] usb 3-2: Creating new data endpoint #3 > [ 2679.322552] usb 3-2: 1:1 Set sample rate 96000, clock 1 > [ 2684.362250] usb 3-2: 2:1: cannot get freq (v2/v3): err -110 > [ 2694.444700] usb 3-2: No valid sample rate available for 2:1, assuming a firmware bug > [ 2694.444707] usb 3-2: 2:1: add audio endpoint 0x84 > [ 2694.444721] usb 3-2: Creating new data endpoint #84 > [ 2699.482103] usb 3-2: 2:1 Set sample rate 96000, clock 1 > > Signed-off-by: Alexander Tsoy <alexander@xxxxxxx> Thanks, applied now. But at the next time, please put maintainers to Cc, so that it can be caught better. Takashi