On Fri, Jul 07, 2023 at 03:20:10PM +0200, Takashi Iwai wrote: > Srinivas Kandagatla wrote: > > yes, the highest value corresponds to lowest dB which is why its inverted. > Ouch, that's a bad design choice... It's moderately common - typically in these cases the control is described in the datasheet as an attenuation control rather than a gain, and this usually corresponds to the physical implementation being only able to make signals smaller relative to the reference.