Re: Audigy bay protocol

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Tue, 2008-07-01 at 12:09 +0200, Takashi Iwai wrote:
> Do you mean that after sending the last two SYSEX, the device returns
> the SYSEX messages above appropriately?  In which timing?

Those two SysEx messages are the (immediate) response to the
initialisation string. The first seems some generic "yes, bay attached,
speaking protocol 2.3" reply, while the second is your initial jack
status.
You could time out on not receiving the "bay attached" message and then
not enable your SysEx listener at all. The actual message will arrive
within a single second, but 5 seconds should be a safe bet.

Once this sequence completes, you will then get jack/button/volume
updates as the event occurs on the bay.

To confirm, the initialisation string is:
echo -en "\xf0\x00\x20\x21\x61\x00\x00\x00\x7f\x00\xf7"
> /dev/snd/midiC0D1

> thanks,
> Takashi

Regards,
Tony V.

Attachment: signature.asc
Description: This is a digitally signed message part

_______________________________________________
Alsa-devel mailing list
Alsa-devel@xxxxxxxxxxxxxxxx
http://mailman.alsa-project.org/mailman/listinfo/alsa-devel