Re: [PATCH] ASoC: cs35l56: Accept values greater than 0 as IRQ numbers

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]



On 17/06/2024 15:04, Mark Brown wrote:
On Mon, Jun 17, 2024 at 02:53:38PM +0100, Simon Trimmer wrote:
IRQ lookup functions such as those in ACPI can return error values when
an IRQ is not defined. The i2c core driver converts the error codes to a
value of 0 and the SPI bus driver passes them unaltered to client device
drivers.

The cs35l56 driver should only accept positive non-zero values as IRQ
numbers.

Have all architectures removed 0 as a valid IRQ?

From discussion threads we can find 0 might still used on x86 for a
legacy device.
But the conversations we can find on this don't seem to exclude passing
a negative error number, just that 0 can normally be assumed invalid.

The kerneldoc for SPI says:

 * @irq: Negative, or the number passed to request_irq() to receive
 *	interrupts from this device.