There was a typo in oxygen mixer code that didn't update the right
channel value properly for the capture volume. Let's fix it.
This trivial fix was originally reported on Bugzilla.
Fixes: a3601560496d ("[ALSA] oxygen: add front panel controls")
Cc: <stable@xxxxxxxxxxxxxxx>
Link: https://bugzilla.kernel.org/show_bug.cgi?id=156561
Signed-off-by: Takashi Iwai <tiwai@xxxxxxx>
---
sound/pci/oxygen/oxygen_mixer.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/sound/pci/oxygen/oxygen_mixer.c b/sound/pci/oxygen/oxygen_mixer.c
index 46705ec77b48..eb3aca16359c 100644
--- a/sound/pci/oxygen/oxygen_mixer.c
+++ b/sound/pci/oxygen/oxygen_mixer.c
@@ -718,7 +718,7 @@ static int ac97_fp_rec_volume_put(struct snd_kcontrol *ctl,
oldreg = oxygen_read_ac97(chip, 1, AC97_REC_GAIN);
newreg = oldreg & ~0x0707;
newreg = newreg | (value->value.integer.value[0] & 7);
- newreg = newreg | ((value->value.integer.value[0] & 7) << 8);
+ newreg = newreg | ((value->value.integer.value[1] & 7) << 8);
change = newreg != oldreg;
if (change)
oxygen_write_ac97(chip, 1, AC97_REC_GAIN, newreg);
--
2.35.3