> - /* See if drive_del isn't supported */ > - if (qemuMonitorJSONHasError(reply, "CommandNotFound")) { > - VIR_ERROR0(_("deleting disk is not supported. " > - "This may leak data if disk is reassigned")); > - ret = 1; > - goto cleanup; > - } else if (qemuMonitorJSONHasError(reply, "DeviceNotFound")) { > - /* NB: device not found errors mean the drive was > - * auto-deleted and we ignore the error */ > - ret = 0; > - } else { > - ret = qemuMonitorJSONCheckError(cmd, reply); > - } > + if (qemuMonitorJSONHasError(reply, "CommandNotFound")) { > + VIR_DEBUG0(_("drive_del command not found, trying HMP")); > + ret = qemuMonitorTextDriveDel(mon, drivestr); > + } else if (qemuMonitorJSONHasError(reply, "DeviceNotFound")) { > + /* NB: device not found errors mean the drive was > + * auto-deleted and we ignore the error */ > + ret = 0; > + } else { > + ret = qemuMonitorJSONCheckError(cmd, reply); > } Looks good, although I think we should issue the "deleting disk is not supported. This may leak data if disk is reassigned" error also in case human-monitor-command is not supported. But that will need some more work on the HMP infrastructure since it's not possible to get this from qemuMonitorText* function that we call. Jirka -- libvir-list mailing list libvir-list@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/libvir-list