Re: [PATCH] virnetdevopenvswitch: Create OVS ports as transient

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 4/22/24 3:56 AM, Michal Privoznik wrote:
Since OVS keeps desired state in a DB, upon sudden crash of the
host we may leave a port behind. There's no problem on VM
shutdown or NIC hotunplug as we call corresponding del-port
function (virNetDevOpenvswitchRemovePort()). But if the host
suddenly crashes we won't ever do that. What happens next, is
when OVS starts it finds desired state in its DB and creates a
stale port.

OVS added support for transient ports in v2.5.0 (Feb 2016) and
since its v2.9.0 it even installs a systemd service
(ovs-delete-transient-ports) that automatically deletes transient
ports on system startup. If we mark a port as transient then OVS
won't restore its state on restart after crash.

This change may render "--may-exist" argument redundant, but I'm
not sure about all the implications if it was removed. Let's keep
it for now.

Resolves: https://gitlab.com/libvirt/libvirt/-/issues/615
Signed-off-by: Michal Privoznik <mprivozn@xxxxxxxxxx>
---
  src/util/virnetdevopenvswitch.c | 4 +++-
  1 file changed, 3 insertions(+), 1 deletion(-)

diff --git a/src/util/virnetdevopenvswitch.c b/src/util/virnetdevopenvswitch.c
index f1765ae1c8..e23f4c83b6 100644
--- a/src/util/virnetdevopenvswitch.c
+++ b/src/util/virnetdevopenvswitch.c
@@ -164,7 +164,9 @@ int virNetDevOpenvswitchAddPort(const char *brname, const char *ifname,
cmd = virNetDevOpenvswitchCreateCmd(&errbuf);
      virCommandAddArgList(cmd, "--", "--may-exist",
-                         "add-port", brname, ifname, NULL);
+                         "add-port", brname, ifname,
+                         "--", "set", "Port", ifname, "other_config:transient=true",
+                         NULL);
virNetDevOpenvswitchConstructVlans(cmd, virtVlan);

While checking this out, I noticed that the machine I was testing on still has ports on its OVS bridge that I had manually created back in 2021 the last time I touched anything related to OVS :-). After adding a new port using the modified commandline, I rebooted the machine and the pre-existing "stale" interfaces were still there, but the one I had just created with transient=true was gone.

Reviewed-by: Laine Stump <laine@xxxxxxxxxx>
_______________________________________________
Devel mailing list -- devel@xxxxxxxxxxxxxxxxx
To unsubscribe send an email to devel-leave@xxxxxxxxxxxxxxxxx




[Index of Archives]     [Virt Tools]     [Libvirt Users]     [Lib OS Info]     [Fedora Users]     [Fedora Desktop]     [Fedora SELinux]     [Big List of Linux Books]     [Yosemite News]     [KDE Users]     [Fedora Tools]