Allow storage migration of VDPA devices by properly checking that they exist on the destionation. Pre-creation is not supported but if the device exists the migration should be able to succeed. Signed-off-by: Peter Krempa <pkrempa@xxxxxxxxxx> --- src/qemu/qemu_migration.c | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-) diff --git a/src/qemu/qemu_migration.c b/src/qemu/qemu_migration.c index 3e0aae4e7c..5e27cd5dbe 100644 --- a/src/qemu/qemu_migration.c +++ b/src/qemu/qemu_migration.c @@ -479,10 +479,13 @@ qemuMigrationDstPrepareStorage(virDomainObj *vm, diskSrcPath = nvmePath; break; + case VIR_STORAGE_TYPE_VHOST_VDPA: + diskSrcPath = disk->src->vdpadev; + break; + case VIR_STORAGE_TYPE_NETWORK: case VIR_STORAGE_TYPE_VOLUME: case VIR_STORAGE_TYPE_VHOST_USER: - case VIR_STORAGE_TYPE_VHOST_VDPA: case VIR_STORAGE_TYPE_LAST: case VIR_STORAGE_TYPE_NONE: break; -- 2.43.0 _______________________________________________ Devel mailing list -- devel@xxxxxxxxxxxxxxxxx To unsubscribe send an email to devel-leave@xxxxxxxxxxxxxxxxx