[PATCH v5 10/10] virsh: Add iothreadadd and iothreaddel commands

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



https://bugzilla.redhat.com/show_bug.cgi?id=1161617

Add command to allow adding and removing IOThreads from the domain including
the configuration and live domain.

$ virsh iothreadadd --help
  NAME
    iothreadadd - add an IOThread to the guest domain

  SYNOPSIS
    iothreadadd <domain> <id> [--config] [--live] [--current]

  DESCRIPTION
    Add an IOThread to the guest domain.

  OPTIONS
    [--domain] <string>  domain name, id or uuid
    [--id] <number>  iothread for the new IOThread
    --config         affect next boot
    --live           affect running domain
    --current        affect current domain

$ virsh iothreaddel --help
  NAME
    iothreaddel - delete an IOThread from the guest domain

  SYNOPSIS
    iothreaddel <domain> <id> [--config] [--live] [--current]

  DESCRIPTION
    Delete an IOThread from the guest domain.

  OPTIONS
    [--domain] <string>  domain name, id or uuid
    [--id] <number>  iothread_id for the IOThread to delete
    --config         affect next boot
    --live           affect running domain
    --current        affect current domain

Assuming a running $dom with multiple IOThreads assigned and that
that the $dom has disks assigned to IOThread 1 and IOThread 2:

$ virsh iothreadinfo $dom
 IOThread ID     CPU Affinity
 ---------------------------------------------------
  1               2
  2               3
  3               0-1

$ virsh iothreadadd $dom 1
error: invalid argument: an IOThread is already using iothread_id '1' in iothreadpids

$ virsh iothreadadd $dom 1 --config
error: invalid argument: an IOThread is already using iothread_id '1' in persistent iothreadids

$ virsh iothreadadd $dom 4
$ virsh iothreadinfo $dom
 IOThread ID     CPU Affinity
 ---------------------------------------------------
  1               2
  2               3
  3               0-1
  4               0-3

$ virsh iothreadinfo $dom --config
 IOThread ID     CPU Affinity
 ---------------------------------------------------
  1               2
  2               3
  3               0-1

$ virsh iothreadadd $dom 4 --config
$ virsh iothreadinfo $dom --config
 IOThread ID     CPU Affinity
  ---------------------------------------------------
    1               2
    2               3
    3               0-1
    4               0-3

Assuming the same original configuration

$ virsh iothreaddel $dom 1
error: invalid argument: cannot remove IOThread 1 since it is being used by disk path '/home/vm-images/f18'

$ virsh iothreaddel $dom 3

$ virsh iothreadinfo $dom
 IOThread ID     CPU Affinity
 ---------------------------------------------------
  1               2
  2               3

$ virsh iothreadinfo $dom --config
 IOThread ID     CPU Affinity
 ---------------------------------------------------
  1               2
  2               3
  3               0-1

Signed-off-by: John Ferlan <jferlan@xxxxxxxxxx>
---
 tools/virsh-domain.c | 164 +++++++++++++++++++++++++++++++++++++++++++++++++++
 tools/virsh.pod      |  31 ++++++++++
 2 files changed, 195 insertions(+)

diff --git a/tools/virsh-domain.c b/tools/virsh-domain.c
index a190050..513f6df 100644
--- a/tools/virsh-domain.c
+++ b/tools/virsh-domain.c
@@ -6896,6 +6896,158 @@ cmdIOThreadPin(vshControl *ctl, const vshCmd *cmd)
 }
 
 /*
+ * "iothreadadd" command
+ */
+static const vshCmdInfo info_iothreadadd[] = {
+    {.name = "help",
+     .data = N_("add an IOThread to the guest domain")
+    },
+    {.name = "desc",
+     .data = N_("Add an IOThread to the guest domain.")
+    },
+    {.name = NULL}
+};
+
+static const vshCmdOptDef opts_iothreadadd[] = {
+    {.name = "domain",
+     .type = VSH_OT_DATA,
+     .flags = VSH_OFLAG_REQ,
+     .help = N_("domain name, id or uuid")
+    },
+    {.name = "id",
+     .type = VSH_OT_INT,
+     .flags = VSH_OFLAG_REQ,
+     .help = N_("iothread for the new IOThread")
+    },
+    {.name = "config",
+     .type = VSH_OT_BOOL,
+     .help = N_("affect next boot")
+    },
+    {.name = "live",
+     .type = VSH_OT_BOOL,
+     .help = N_("affect running domain")
+    },
+    {.name = "current",
+     .type = VSH_OT_BOOL,
+     .help = N_("affect current domain")
+    },
+    {.name = NULL}
+};
+
+static bool
+cmdIOThreadAdd(vshControl *ctl, const vshCmd *cmd)
+{
+    virDomainPtr dom;
+    int iothread_id = 0;
+    bool ret = false;
+    bool config = vshCommandOptBool(cmd, "config");
+    bool live = vshCommandOptBool(cmd, "live");
+    bool current = vshCommandOptBool(cmd, "current");
+    unsigned int flags = VIR_DOMAIN_AFFECT_CURRENT;
+
+    VSH_EXCLUSIVE_OPTIONS_VAR(current, live);
+    VSH_EXCLUSIVE_OPTIONS_VAR(current, config);
+
+    if (config)
+        flags |= VIR_DOMAIN_AFFECT_CONFIG;
+    if (live)
+        flags |= VIR_DOMAIN_AFFECT_LIVE;
+
+    if (!(dom = vshCommandOptDomain(ctl, cmd, NULL)))
+        return false;
+
+    if (vshCommandOptInt(cmd, "id", &iothread_id) < 0 || iothread_id <= 0) {
+        vshError(ctl, _("Invalid IOThread id value: '%d'"), iothread_id);
+        goto cleanup;
+    }
+
+    if (virDomainAddIOThread(dom, iothread_id, flags) < 0)
+        goto cleanup;
+
+    ret = true;
+
+ cleanup:
+    virDomainFree(dom);
+    return ret;
+}
+
+/*
+ * "iothreaddel" command
+ */
+static const vshCmdInfo info_iothreaddel[] = {
+    {.name = "help",
+     .data = N_("delete an IOThread from the guest domain")
+    },
+    {.name = "desc",
+     .data = N_("Delete an IOThread from the guest domain.")
+    },
+    {.name = NULL}
+};
+
+static const vshCmdOptDef opts_iothreaddel[] = {
+    {.name = "domain",
+     .type = VSH_OT_DATA,
+     .flags = VSH_OFLAG_REQ,
+     .help = N_("domain name, id or uuid")
+    },
+    {.name = "id",
+     .type = VSH_OT_INT,
+     .flags = VSH_OFLAG_REQ,
+     .help = N_("iothread_id for the IOThread to delete")
+    },
+    {.name = "config",
+     .type = VSH_OT_BOOL,
+     .help = N_("affect next boot")
+    },
+    {.name = "live",
+     .type = VSH_OT_BOOL,
+     .help = N_("affect running domain")
+    },
+    {.name = "current",
+     .type = VSH_OT_BOOL,
+     .help = N_("affect current domain")
+    },
+    {.name = NULL}
+};
+
+static bool
+cmdIOThreadDel(vshControl *ctl, const vshCmd *cmd)
+{
+    virDomainPtr dom;
+    int iothread_id = 0;
+    bool ret = false;
+    bool config = vshCommandOptBool(cmd, "config");
+    bool live = vshCommandOptBool(cmd, "live");
+    bool current = vshCommandOptBool(cmd, "current");
+    unsigned int flags = VIR_DOMAIN_AFFECT_CURRENT;
+
+    VSH_EXCLUSIVE_OPTIONS_VAR(current, live);
+    VSH_EXCLUSIVE_OPTIONS_VAR(current, config);
+
+    if (config)
+        flags |= VIR_DOMAIN_AFFECT_CONFIG;
+    if (live)
+        flags |= VIR_DOMAIN_AFFECT_LIVE;
+
+    if (!(dom = vshCommandOptDomain(ctl, cmd, NULL)))
+        return false;
+
+    if (vshCommandOptInt(cmd, "id", &iothread_id) < 0 || iothread_id <= 0) {
+        vshError(ctl, _("Invalid IOThread id value: '%d'"), iothread_id);
+        goto cleanup;
+    }
+
+    if (virDomainDelIOThread(dom, iothread_id, flags) < 0)
+        goto cleanup;
+
+    ret = true;
+
+ cleanup:
+    virDomainFree(dom);
+    return ret;
+}
+
+/*
  * "cpu-compare" command
  */
 static const vshCmdInfo info_cpu_compare[] = {
@@ -12845,6 +12997,18 @@ const vshCmdDef domManagementCmds[] = {
      .info = info_iothreadpin,
      .flags = 0
     },
+    {.name = "iothreadadd",
+     .handler = cmdIOThreadAdd,
+     .opts = opts_iothreadadd,
+     .info = info_iothreadadd,
+     .flags = 0
+    },
+    {.name = "iothreaddel",
+     .handler = cmdIOThreadDel,
+     .opts = opts_iothreaddel,
+     .info = info_iothreaddel,
+     .flags = 0
+    },
     {.name = "send-key",
      .handler = cmdSendKey,
      .opts = opts_send_key,
diff --git a/tools/virsh.pod b/tools/virsh.pod
index d642a69..091abc6 100644
--- a/tools/virsh.pod
+++ b/tools/virsh.pod
@@ -1416,6 +1416,37 @@ If no flag is specified, behavior is different depending on hypervisor.
 B<Note>: The expression is sequentially evaluated, so "0-15,^8" is
 identical to "9-14,0-7,15" but not identical to "^8,0-15".
 
+=item B<iothreadadd> I<domain> I<iothread_id>
+[[I<--config>] [I<--live>] | [I<--current>]]
+
+Add a new IOThread to the domain using the specified I<iothread_id>.
+If the I<iothread_id> already exists, the command will fail. The
+I<iothread_id> must be greater than zero.
+
+If I<--live> is specified, affect a running guest. If the guest is not
+running an error is returned.
+If I<--config> is specified, affect the next boot of a persistent guest.
+If I<--current> is specified or I<--live> and I<--config> are not specified,
+affect the current guest state.
+Both I<--live> and I<--config> flags may be given, but if not flag is
+specified, behavior is different depending on hypervisor.
+
+=item B<iothreaddel> I<domain> I<iothread_id>
+[[I<--config>] [I<--live>] | [I<--current>]]
+
+Delete an IOThread from the domain using the specified I<iothread_id>.
+If an IOThread is currently assigned to a disk resource such as via the
+B<attach-disk> command, then the attempt to remove the IOThread will fail.
+If the I<iothread_id> does not exist an error will occur.
+
+If I<--live> is specified, affect a running guest. If the guest is not
+running an error is returned.
+If I<--config> is specified, affect the next boot of a persistent guest.
+If I<--current> is specified or I<--live> and I<--config> are not specified,
+affect the current guest state.
+Both I<--live> and I<--config> flags may be given, but if not flag is
+specified, behavior is different depending on hypervisor.
+
 =item B<managedsave> I<domain> [I<--bypass-cache>]
 [{I<--running> | I<--paused>}] [I<--verbose>]
 
-- 
2.1.0

--
libvir-list mailing list
libvir-list@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/libvir-list




[Index of Archives]     [Virt Tools]     [Libvirt Users]     [Lib OS Info]     [Fedora Users]     [Fedora Desktop]     [Fedora SELinux]     [Big List of Linux Books]     [Yosemite News]     [KDE Users]     [Fedora Tools]