On Mon, Apr 13, 2015 at 17:21:11 -0400, John Ferlan wrote: > Check the proposed pool source host XML definition against existing gluster > pools to ensure the incoming definition doesn't use the same source host XML > definition as an existing pool. > > Signed-off-by: John Ferlan <jferlan@xxxxxxxxxx> > --- > src/conf/storage_conf.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/src/conf/storage_conf.c b/src/conf/storage_conf.c > index 2b2104d..0a50f57 100644 > --- a/src/conf/storage_conf.c > +++ b/src/conf/storage_conf.c > @@ -2545,13 +2545,13 @@ virStoragePoolSourceFindDuplicate(virConnectPtr conn, > matchpool = virStoragePoolSourceFindDuplicateDevices(pool, def); > break; > case VIR_STORAGE_POOL_SHEEPDOG: > + case VIR_STORAGE_POOL_GLUSTER: Gluster still can host multiple pools on a single host:port combination. You also need to check that pool->def->source.dir are same among the two pool definitions. > if (virStoragePoolSourceMatchSingleHost(&pool->def->source, > &def->source)) > matchpool = pool; > break; > case VIR_STORAGE_POOL_MPATH: > case VIR_STORAGE_POOL_RBD: > - case VIR_STORAGE_POOL_GLUSTER: > case VIR_STORAGE_POOL_ZFS: > case VIR_STORAGE_POOL_LAST: > break; ACK if you add the directory check. Peter