I have an issue re-kickstarting RHEL 4 servers when I need to redploy
them. I have HP Linux servers that the CCISS raid controller (came out of
Compaq). The disk presented by this raid controller should up as /dev/cciss/c#d#.
If I have the systems connected to SAN storage then they show up as /dev/sd[a,
b,c, etc.]. If I try to kickstart a HP server that has SAN devices already
zoned to it the kickstart process fails with “Input/output error during
write on /dev/sda” error. Does anyone know what could be the
problem and how to address. I’m would like to eleminate having to
disconnecting the fiber connections or unzoning luns. Here’s my partition section of the ks.cfg zerombr yes clearpart --drives=cciss/c0d0,cciss/c0d1 --all part swap --start=1 --end=800 --ondisk cciss/c0d0 --asprimary part / --fstype ext3 --start=801 --end=1057 --ondisk cciss/c0d0 --asprimary part pv.00 --size 1 --grow --asprimary --ondisk cciss/c0d0 volgroup vg00 pv.00 logvol /usr --vgname=vg00 --size=2024 --name=lvol1 logvol /var --vgname=vg00 --size=4096 --name=lvol2 logvol /home --vgname=vg00 --size=1024 --name=lvol3 logvol /opt --vgname=vg00 --size=4096 --name=lvol4