On Thu, 14 Oct 2021 at 22:29, ToddAndMargo via users <users@xxxxxxxxxxxxxxxxxxxxxxx> wrote:
On 10/13/21 06:38, George N. White III wrote:
> Also available in fedora): nvmi-cli (upstream
> https://github.com/linux-nvme/nvme-cli)
> <https://github.com/linux-nvme/nvme-cli>
> and nvmetcli (Configure NVMe-over-Fabrics Target).
see anything wrong?
# nvme smart-log /dev/nvme0n1
Smart Log for NVME device:nvme0n1 namespace-id:ffffffff
critical_warning : 0
temperature : 31 C
available_spare : 100%
available_spare_threshold : 10%
percentage_used : 1%
When working properly, the drive dies when it uses up all the
"available_spare" capacity. This report is similar to what I
see, but I only have 3 nvme drives.
There are failure modes other than something that
degrades over time and can be monitored.
endurance group critical warning summary: 0
data_units_read : 773,858,127
data_units_written : 38,056,140
host_read_commands : 2,212,795,501
host_write_commands : 822,976,235
controller_busy_time : 5,347
power_cycles : 1,718
power_on_hours : 3,405
unsafe_shutdowns : 63
media_errors : 0
num_err_log_entries : 1,828
I have 1,812 for
num_err_log_entries on a new drive
(291
power_on_hours), so I suspect many of
these log entries come when a drive is first
installed.
Warning Temperature Time : 0
Critical Composite Temperature Time : 0
Temperature Sensor 1 : 31 C
Temperature Sensor 2 : 34 C
Thermal Management T1 Trans Count : 0
Thermal Management T2 Trans Count : 0
Thermal Management T1 Total Time : 0
Thermal Management T2 Total Time : 0
TLDNR:
George N. White III
_______________________________________________ users mailing list -- users@xxxxxxxxxxxxxxxxxxxxxxx To unsubscribe send an email to users-leave@xxxxxxxxxxxxxxxxxxxxxxx Fedora Code of Conduct: https://docs.fedoraproject.org/en-US/project/code-of-conduct/ List Guidelines: https://fedoraproject.org/wiki/Mailing_list_guidelines List Archives: https://lists.fedoraproject.org/archives/list/users@xxxxxxxxxxxxxxxxxxxxxxx Do not reply to spam on the list, report it: https://pagure.io/fedora-infrastructure