Re: smartmontools still "monitoring" a replaced hard drive.

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



The "df" command gives me this:
-----
bash.1[~]: df
Filesystem     1K-blocks     Used Available Use% Mounted on
devtmpfs         8174992        0   8174992   0% /dev
tmpfs            8186908    27688   8159220   1% /dev/shm
tmpfs            8186908     1808   8185100   1% /run
tmpfs            8186908        0   8186908   0% /sys/fs/cgroup
/dev/sda6       51475068 30103124  18734120  62% /
tmpfs            8186908       28   8186880   1% /tmp
/dev/sda3         487652   215053    242903  47% /boot
/dev/sda7      947624164  8118256 891346268   1% /home
tmpfs            1637380       24   1637356   1% /run/user/0
bash.2[~]
-----
The "smartctl" command with a parameter of "sda3" gives me this:
-----
bash.7[~]: smartctl -a /dev/sda3
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.14.13-200.fc26.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     ST2000DM006-2DM164
Serial Number:    Z4Z89YG1
LU WWN Device Id: 5 000c50 0a3169115
Firmware Version: CC26
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Wed Jan 24 15:08:04 2018 MST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(   80) seconds.
Offline data collection
capabilities: 			 (0x73) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					No Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 207) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x1085)	SCT Status supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   117   099   006    Pre-fail  Always       -       162318392
  3 Spin_Up_Time            0x0003   096   096   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       524
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   073   060   030    Pre-fail  Always       -       24305368
  9 Power_On_Hours          0x0032   098   098   000    Old_age   Always       -       2614
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       524
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   063   058   045    Old_age   Always       -       37 (Min/Max 36/39)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       0
193 Load_Cycle_Count        0x0032   074   074   000    Old_age   Always       -       53764
194 Temperature_Celsius     0x0022   037   042   000    Old_age   Always       -       37 (0 17 0 0 0)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       1717 (118 144 0)
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       1779480900
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       88879919912

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%         5         -
# 2  Short offline       Completed without error       00%         3         -
# 3  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

bash.8[~]:
-----
This looks like the output I was getting last spring, when the old hard drive was dying.  The current drive, a new drive, was installed at that time (late June).  It's as if smartctl is at least in part simply re-displaying results from the last run I did on the old drive last June.

Also, the output is basically the same whether the smartctl parameter is "sda", "sda3", or "sd?".

The "Disks" I was referring to is what Samuel identified.
_______________________________________________
users mailing list -- users@xxxxxxxxxxxxxxxxxxxxxxx
To unsubscribe send an email to users-leave@xxxxxxxxxxxxxxxxxxxxxxx



[Index of Archives]     [Older Fedora Users]     [Fedora Announce]     [Fedora Package Announce]     [EPEL Announce]     [EPEL Devel]     [Fedora Magazine]     [Fedora Summer Coding]     [Fedora Laptop]     [Fedora Cloud]     [Fedora Advisory Board]     [Fedora Education]     [Fedora Security]     [Fedora Scitech]     [Fedora Robotics]     [Fedora Infrastructure]     [Fedora Websites]     [Anaconda Devel]     [Fedora Devel Java]     [Fedora Desktop]     [Fedora Fonts]     [Fedora Marketing]     [Fedora Management Tools]     [Fedora Mentors]     [Fedora Package Review]     [Fedora R Devel]     [Fedora PHP Devel]     [Kickstart]     [Fedora Music]     [Fedora Packaging]     [Fedora SELinux]     [Fedora Legal]     [Fedora Kernel]     [Fedora OCaml]     [Coolkey]     [Virtualization Tools]     [ET Management Tools]     [Yum Users]     [Yosemite News]     [Gnome Users]     [KDE Users]     [Fedora Art]     [Fedora Docs]     [Fedora Sparc]     [Libvirt Users]     [Fedora ARM]

  Powered by Linux