On 20.6.2014 20:58, lee wrote:
Hi,
what type of cable am I supposed to put into apcupsd.conf for an UPS
which is connected to a remote computer and monitored over the network?
Hi Lee.
I have two machines powered by one UPS. M1 controls UPS over USB cable,
M2 is neighboring machine.
/etc/apcupsd/apcupsd.conf on M1 contains:
UPSCABLE usb
UPSTYPE usb
DEVICE
...
NETSERVER on
NISIP <M1_ip_address_here>
NISPORT 3551
...
/etc/apcupsd/apcupsd.conf on M2 contains:
UPSCABLE ether
UPSTYPE net
DEVICE <M1_ip_address_here>:3551
...
NETSERVER on
NISIP 127.0.0.1
NISPORT 3551
...
This setup works for me. M1 and M2 does correct shutdown on power fail.
Maybe this helps.
Vlado
--