On Mon October 2 2006 11:04 pm, Claude Jones wrote: > I'm running a long one now, and it says it will take 111 > minutes - so I wait. Here are the results: doesn't look to me like my drive is the problem. If any one has any other ideas, I'm bereft. smartctl -a /dev/sda -d ata smartctl version 5.36 [i686-redhat-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus family Device Model: ST3160023AS Serial Number: 3JS0JS3W Firmware Version: 3.05 User Capacity: 160,041,885,696 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 6 ATA Standard is: ATA/ATAPI-6 T13 1410D revision 2 Local Time is: Tue Oct 3 00:55:15 2006 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 111) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 057 050 006 Pre-fail Always - 125020748 3 Spin_Up_Time 0x0003 096 096 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 0 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 089 060 030 Pre-fail Always - 918835159 9 Power_On_Hours 0x0032 081 081 000 Old_age Always - 17138 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 099 099 020 Old_age Always - 1790 194 Temperature_Celsius 0x0022 031 056 000 Old_age Always - 31 195 Hardware_ECC_Recovered 0x001a 057 049 000 Old_age Always - 125020748 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 1 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 1 199 UDMA_CRC_Error_Count 0x003e 200 197 000 Old_age Always - 3 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 17137 - # 2 Short offline Completed without error 00% 17136 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. -- Claude Jones Brunswick, MD, USA -- fedora-list mailing list fedora-list@xxxxxxxxxx To unsubscribe: https://www.redhat.com/mailman/listinfo/fedora-list